Allegato 1 - Rilievo danni e quadro fessurativo
Pillar damage with detachment of the external face
building damage
Bead head damage on pillar support
Internal pillar after reinforcement of the plinth and of the pillar / beam connection
Exterior view of the shed after the intervention
Bunk head reinforcement in concrete: final shaving with inorganic matrix cement mortar
Bead-tested reinforcement: a second layer of PBO fiberglass FRCM system
Reinforced head beam reinforcement: final finishing with inorganic matrix cement mortar
Damage in the corner
Damage on internal pillar
Connection between pillar and industrial floor: reinforcement by confinement with HPFRCC micro-concrete
Internal masonry prevention: masonry removal on the first floor for the application of PBO fiber FRCM system
Internal masonry prevention intervention: positioning of the network strip in PBO system FRCM
Internal masonry prevention intervention: particular reinforcing fiber connection with XJoint